362 research outputs found

    Determination of Pericardial Adipose Tissue Increases the Prognostic Accuracy of Coronary Artery Calcification for Future Cardiovascular Events

    Get PDF
    Objectives: Pericardial adipose tissue (PAT) is associated with coronary artery plaque accumulation and the incidence of coronary heart disease. We evaluated the possible incremental prognostic value of PAT for future cardiovascular events. Methods: 145 patients (94 males, age 60 10 years) with stable coronary artery disease underwent coronary artery calcification (CAC) scanning in a multislice CT scanner, and the volume of pericardial fat was measured. Mean observation time was 5.4 years. Results: 34 patients experienced a severe cardiac event. They had a significantly higher CAC score (1,708 +/- 2,269 vs. 538 +/- 1,150, p 400, 3.5 (1.9-5.4; p = 0.007) for scores > 800 and 5.9 (3.7-7.8; p = 0.005) for scores > 1,600. When additionally a PAT volume > 200 cm(3) was determined, there was a significant increase in the event rate and relative risk. We calculated a relative risk of 2.9 (1.9-4.2; p = 0.01) for scores > 400, 4.0 (2.1-5.0; p = 0.006) for scores > 800 and 7.1 (4.1-10.2; p = 0.005) for scores > 1,600. Conclusions:The additional determination of PAT increases the predictive power of CAC for future cardiovascular events. PAT might therefore be used as a further parameter for risk stratification. Copyright (C) 2012 S. Karger AG, Base

    Health behavior modification after electron beam computed tomography and physician consultation

    Get PDF
    This study aimed to determine whether participants reported altering health behaviors (physical activity, diet, and alcohol consumption) after seeing results from an electron-beam computed tomography (EBCT) scan for coronary artery calcium and reviewing these results with a physician. Clinicians attempt to motivate patients to control cardiovascular risk factors by adopting healthy behaviors and reducing harmful actions. Asymptomatic patients (N = 510) were evaluated by EBCT for the extent of coronary artery calcium. Information pertaining to demographics, health history, and lifestyle/health behaviors was obtained from each participant at the time of the EBCT scan. Patients were given their numerical calcium score, shown images of their coronary arteries, and counseled by a physician for lifestyle and medical risk modification based on their coronary artery calcium score. Approximately 6 years after the scan, participants completed a follow-up questionnaire related to lifestyle modifications. In multivariable analysis, the presence and extent of coronary artery calcium was significantly associated with beneficial health behavior modifications. Specifically, the greater a patient’s coronary artery calcium score, the more likely they were to report increasing exercise (odds ratio = 1.34, P = 0.02), changing diet (odds ratio = 1.40, P < 0.01), and changing alcohol intake (odds ratio = 1.46, P = 0.05). This study suggests that seeing and being counseled on the presence and extent of coronary artery calcium is significantly associated with behavior change

    Coronary calcium mass scores measured by identical 64-slice MDCT scanners are comparable: a cardiac phantom study

    Get PDF
    To assess whether absolute mass scores are comparable or differ between identical 64-slice MDCT scanners of the same manufacturer and to compare absolute mass scores to the physical mass and between scan modes using a calcified phantom. A non-moving anthropomorphic phantom with nine calcifications of three sizes and three densities was scanned 30 times on three 64-slice MDCT scanners of manufacturer A and on three 64-slice MDCT scanners of manufacturer B in both sequential and spiral scan mode. The mean mass scores and mass score variabilities of seven calcifications were determined for all scanners; two non-detectable calcifications were omitted. It was analyzed whether identical scanners yielded similar or significantly different mass scores. Furthermore mass scores were compared to the physical mass and mass scores were compared between scan modes. The mass score calibration factor was determined for all scanners. Mass scores obtained on identical scanners were similar for almost all calcifications. Overall, mass score differences between the scanners were small ranging from 1.5 to 3.4% for the total mass scores, and most differences between scanners were observed for high density calcifications. Mass scores were significantly different from the physical mass for almost all calcifications and all scanners. In sequential mode the total physical mass (167.8 mg) was significantly overestimated (+2.3%) for 4 out of 6 scanners. In spiral mode a significant overestimation (+2.5%) was found for system B and a significant underestimation (−1.8%) for two scanners of system A. Mass scores were dependent on the scan mode, for manufacturer A scores were higher in sequential mode and for manufacturer B in spiral mode. For system A using spiral scan mode no differences were found between identical scanners, whereas a few differences were found using sequential mode. For system B the scan mode did not affect the number of different mass scores between identical scanners. Mass scores obtained in the same scan mode are comparable between identical 64-slice CT scanners and identical 64-slice CT scanners on different sites can be used in follow-up studies. Furthermore, for all systems significant differences were found between mass scores and the physical calcium mass; however, the differences were relatively small and consistent

    Calcium scoring using 64-slice MDCT, dual source CT and EBT: a comparative phantom study

    Get PDF
    Purpose Assessment of calcium scoring (Ca-scoring) on a 64-slice multi-detector computed tomography (MDCT) scanner, a dual-source computed tomography (DSCT) scanner and an electron beam tomography (EBT) scanner with a moving cardiac phantom as a function of heart rate, slice thickness and calcium density. Methods and materials Three artificial arteries with inserted calcifications of different sizes and densities were scanned at rest (0 beats per minute) and at 50–110 beats per minute (bpm) with an interval of 10 bpm using 64-slice MDCT, DSCT and EBT. Images were reconstructed with a slice thickness of 0.6 and 3.0 mm. Agatston score, volume score and equivalent mass score were determined for each artery. A cardiac motion susceptibility (CMS) index was introduced to assess the susceptibility of Ca-scoring to heart rate. In addition, a difference (Δ) index was introduced to assess the difference of absolute Ca-scoring on MDCT and DSCT with EBT. Results Ca-score is relatively constant up to 60 bpm and starts to decrease or increase above 70 bpm, depending on scoring method, calcification density and slice thickness. EBT showed the least susceptibility to cardiac motion with the smallest average CMS-index (2.5). The average CMS-index of 64-slice MDCT (9.0) is approximately 2.5 times the average CMS-index of DSCT (3.6). The use of a smaller slice thickness decreases the CMS-index for both CT-modalities. The Δ-index for DSCT at 0.6 mm (53.2) is approximately 30% lower than the Δ-index for 64-slice MDCT at 0.6 mm (72.0). The Δ-indexes at 3.0 mm are approximately equal for both modalities (96.9 and 102.0 for 64-slice MDCT and DSCT respectively). Conclusion Ca-scoring is influenced by heart rate, slice thickness and modality used. Ca-scoring on DSCT is approximately 50% less susceptible to cardiac motion as 64-slice MDCT. DSCT offers a better approximation of absolute calcium score on EBT than 64-slice MDCT when using a smaller slice thickness. A smaller slice thickness reduces the susceptibility to cardiac motion and reduces the difference between CT-data and EBT-data. The best approximation of EBT on CT is found for DSCT with a slice thickness of 0.6 mm

    Is there a role for CT coronary angiography in patients with symptomatic angina? Effect of coronary calcium score on identification of stenosis

    Get PDF
    Present guidelines discourage the use of CT coronary angiography (CTCA) in symptomatic angina patients. We examined the relation between coronary calcium score (CS) and the performance of CTCA in patients with stable and unstable angina in order to understand under which conditions CTCA might be a gate-keeper to conventional coronary angiography (CCA) in such patients. We included 360 patients between 50 and 70 years old with stable and unstable angina who were clinically referred for CCA irrespective of CS. Patients received CS and CCTA on 64-slice scanners in a multicenter cross-sectional trial. The institutional review board approved the study. Diagnostic performance of CTCA to detect or rule out significant coronary artery disease was calculated on a per patient level in pre-defined CS categories. The prevalence of significant coronary artery disease strongly increased with CS. Negative CTCA were associated with a negative likelihood ratio of <0.1 independent of CS. Positive CTCA was associated with a high positive likelihood ratio of 9.4 if CS was <10. However, for higher CS the positive likelihood ratio never exceeded 3.0 and for CS >400 it decreased to 1.3. In the 62 (17%) patients with CS <10, CTCA reliably identified the 42 (68%) of these patients without significant CAD, at no false negative CTCA scans. In symptomatic angina patients, a negative CTCA reliably excludes significant CAD but the additional value of CTCA decreases sharply with CS >10 and especially with CS >400. In patients with CS <10, CTCA provides excellent diagnostic performance

    Inter-scan reproducibility of coronary calcium measurement using Multi Detector-Row Computed Tomography (MDCT)

    Get PDF
    Purpose: To assess inter-scan reproducibility of coronary calcium measurements obtained from Multi Detector-Row CT (MDCT) images and to evaluate whether this reproducibility is affected by different measurement protocols, slice thickness, cardiovascular risk factors and/or technical variables. Design: Cross-sectional study with repeated measurements. Materials and methods: The study population comprised 76 healthy women. Coronary calcium was assessed in these women twice in one session using 16-MDCT (Philips Mx 8000 IDT 16). Images were reconstructed with 1.5 mm slice thickness and 3.0 mm slice thickness. The 76 repeated scans were scored. The Agatston score, a volume measurement and a mass measurement were assessed. Reproducibility was determined by estimation of mean, absolute, relative difference, the weighted kappa value for agreement and the Intra-class correlation coefficient (ICCC). Results: Fifty-five participants (72.4%) had a coronary calcification of more than zero in Agatston (1.5 mm slice thickness). The reproducibility of coronary calcium measurements between scans in terms of ranking was excellent with Intra-class correlation coefficients of >0.98, and kappa values above 0.80. The absolute difference in calcium score between scans increased with increasing calcium levels, indicating that measurement error increases with increasing calcium levels. However, no relation was found between the mean difference in scores and calcium levels, indicating that the increase in measurement error is likely to result in random misclassification in calcium score. Reproducibility results were similar for 1.5 mm slices and for 3.0 mm slices, and equal for Agatston, volume and mass measurements. Conclusion: Inter-scan reproducibilility of measurement of coronary calcium using images from MDCT is excellent, irrespective of slice thickness and type of calcium parameter

    Progression of coronary calcification in healthy postmenopausal women

    Get PDF
    BACKGROUND: Coronary artery calcium score incrementally improves coronary risk prediction beyond that provided by conventional risk factors. Limited information is available regarding rates of progression of coronary calcification in women, particularly those with baseline scores above zero. Further, determinants of progression of coronary artery calcification in women are not well understood. This study prospectively evaluated rates and determinants of progression of coronary artery calcium score in a group of healthy postmenopausal women. METHODS: We determined coronary calcium score by computed tomography and recorded demographic, lifestyle and health characteristics of 914 postmenopausal women, a subset of those enrolled in the Women's Health Initiative Observational Study. The 305 women with calcium score ≥10 Agatston units at baseline were invited for repeat scan. This analysis includes the 94 women who underwent second scans. RESULTS: Mean age of study participants was 65 ± 9 years (mean ± SD), body mass index was 26.1 ± 6.1 kg/m(2), and baseline calcium score was 162 ± 220 Agatston units. Mean interval between scans was 3.3 ± 0.7 years. A wide range of changes in coronary calcium score was observed, from -53 to +452 Agatston units/year. Women with lower scores at baseline had smaller annual increases in absolute calcium score. Coronary calcium scores increased 11, 31 and 79 Agatston units/year among women with baseline calcium score in the lowest, middle and highest tertiles. In multivariate analysis, age was not an independent predictor of absolute change in coronary calcium score. Hydroxymethylglutaryl coenzyme A reductase inhibitor (statin) use at baseline was a negative predictor (p = 0.015), whereas baseline calcium score was a strong, positive predictor (p < 0.0001) of progression of coronary calcification. CONCLUSION: Among postmenopausal women with coronary calcium score ≥ 10 Agatston units, rates of change of coronary calcium score varied widely. In multivariate analysis, statin use was a negative independent determinant, whereas baseline calcium score was a strong positive predictor of annual change in coronary calcium score

    Diagnostic accuracy of computed tomography coronary angiography in patients with a zero calcium score

    Get PDF
    To evaluate the diagnostic accuracy of 64-slice CT coronary angiography (CT-CA) for the detection of significant coronary artery stenosis in patients with zero on the Agatston Calcium Score (CACS). We enrolled 279 consecutive patients (96 male, mean age 48±12 years) with suspected coronary artery disease. Patients were symptomatic (n=208) or asymptomatic (n=71), and underwent conventional coronary angiography (CAG). For CT-CA we administered an IV bolus of 100 ml of iodinated contrast material. CT-CA was compared to CAG using a threshold for significant stenosis of ≤50%. The prevalence of disease demonstrated at CAG was 15% (1.4% in asymptomatic). The population at CAG showed no or non-significant disease in 85% (238/279), single vessel disease in 9% (25/279), and multi-vessel disease in 6% (16/279). Sensitivity, specificity, and positive and negative predictive values of CT-CA vs. CAG on the patient level were 100%, 95%, 76%, and 100% in the overall population and 100%, 100%, 100%, and 100% in asymptomatic patients, respectively. CT-CA proves high diagnostic performance in patients with or without symptoms and with zero CACS. The prevalence of significant disease detected by CT-CA was not negligible in asymptomatic patients. The role of CT-CA in asymptomatic patients remains uncertain